Fire Alarm
HST HC102
HST HC102The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system.
HST YT-102-C
HST YT-102-CConventional Photoelectric Smoke Detector
- Operating Voltage Range: 16 to 28VDC Volts Non-polarized
- Standby Current: 60μA @ 28 VDC(Maximum)
- Alarm Current (LED on: ) 30mA @ 28 VDC(Maximum)
- Adjustable Sensitivity: 0.1 to 0.3dB/m
- Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
HS103
HS103Description & Features
• Operating Temperature •1o•c to so•c
• Operating Humidity 0 to 95 RH,
• No condensation or Icing
• Operating Voltage 22VDC to 30VDC
• Average Current 70 mA
• Light Output 1.2 WS
• Flash Rate 2 seconds
• Sound Level 1OOdB
• Light Life 30000 flashes
HP101U-4
HP101U-4The HP101U Series ConventionalFire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective IDC1000 Series can be used in a variety of low- to mid-sized applications.
Morley-IAS Addressable Smoke Detector
Morley-IAS Addressable Smoke Detector• Genuine and fast response
• Advanced protocol and smoothing filter to suppress false alarm
• Rotary decade address switches
• Analog addressable communication
• Dual integrated LED for 360° visibility
• Specification: EN54-7
• LPCB approved
• Environment friendly – meets RoHS legislative requirements
DXc4 Four Loop
DXc4 Four LoopFour Loop Control Panel, 230Vac, 2 sounder circuits.
Dims 391.5 x 390 x 147mm (H x W x D)
The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.
The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs.
In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.
Morley Heat Detector
Morley Heat DetectorMorley-IAS addressable Heat detectors
• Advanced protocol and smoothing filter to suppress false alarm
• Rotary decade address switches
• Analog addressable communication
• Dual integrated LED for 360° visibility
• Specification: EN54-5 – Fixed 58º thermal detector
Addressable Optical Beam Detector
Addressable Optical Beam DetectorMorley Addressable Optical Beam Detector
• Combined transmitter and receiver unit
• Range 10-100 metres
• 4 x fixed sensitivity/threshold levels
• 2 x automatic variable sensitivity modes
• Operates in the Infra-Red light spectrum
Morley Manual Call Point
Morley Manual Call PointMORLEY-IAS Addressable Manual Call Point
•Unique ‘Plug & Play’ installation concept
•Analogue addressable communications
•Semi-Flush or surface mounting (optional back-box)
•EN54-compliant
•Integral LED
Morley Wall Sounder
Morley Wall SounderMORLEY-IAS Addressable Wall Sounder Beacon
Intelligent Wall Mounted Sounder Strobe
Pure White
skirt, Red lens